Solenoid Inductance Calculator – L = μ₀N²A/l for an Air-Cored Coil
Use this free Solenoid Inductance Calculator to find the self-inductance of an air-cored solenoid, L = μ0N²A ÷ l — and see why the turns count, squared, is the designer's most powerful lever.
Formula
L = μ0 × N² × A ÷ l • L in henries (H), A in m², l in metres, μ0 = 4π × 10⁻⁷. The formula assumes a long, tightly wound, air-cored solenoid. The N² appears because each turn both carries current and links the flux made by all the others — double the turns, quadruple the inductance.
How to use
- Enter the number of turns and the coil's cross-sectional area in cm² (converted to m² for you).
- Enter the length of the winding in metres.
- Click "Calculate" to get the inductance in henries and millihenries.
Worked example
A solenoid has N = 500 turns, cross-section A = 10 cm² (= 0.001 m²) and length l = 0.2 m.
L = μ0N²A ÷ l = (4π × 10⁻⁷) × 500² × 0.001 ÷ 0.2 = (4π × 10⁻⁷) × 250,000 × 0.001 ÷ 0.2 = 1.571 × 10⁻³ H = 1.571 mH.
Winding the same wire into 1,000 turns instead would give about 6.28 mH — four times the inductance from twice the turns, exactly as the N² promises.
FAQ
What changes if I add an iron core?
The core's relative permeability μr multiplies the inductance: L = μrμ0N²A/l. With μr of several hundred for iron, the same coil can jump from millihenries to several henries — until the core saturates.
Does the formula work for short, fat coils?
Only approximately. It assumes the field inside is uniform, which holds when the length is much greater than the diameter. Short coils leak more flux at the ends, so their true inductance is somewhat lower.
Why doesn't the current appear in the formula?
For an air core, inductance is purely a property of the coil's geometry — the flux linkage per amp is the same at any current. (Iron cores break this rule once they begin to saturate.)