Transformer Turns Solver Calculator – Find Vs, Vp, Ns or Np from Vs/Vp = Ns/Np

Use this free Transformer Turns Solver to find any one missing value in the transformer equation Vs ÷ Vp = Ns ÷ Np — an output voltage, an input voltage, or either turns count.

Vp, Np Vs, Ns iron core links both coils

Formula

Vs ÷ Vp = Ns ÷ Np  •  the voltage across each coil is proportional to its number of turns, because both coils share the same changing magnetic flux in the core. Rearranged: Vs = Vp × Ns ÷ Np  •  Ns = Np × Vs ÷ Vp  •  and likewise for Vp and Np. This is the ideal-transformer relation (real transformers lose a few percent as heat).

How to use

Worked example

A transformer has Np = 1200 turns on the primary, connected to Vp = 240 V. How many secondary turns give a 20 V output — or, with Ns = 100 turns, what is Vs?
Vs = Vp × Ns ÷ Np = 240 × 100 ÷ 1200 = 20 V.
The turns ratio is 12 : 1, so the voltage drops by the same factor of 12 — a step-down transformer, exactly what a phone-charger or doorbell supply needs (before rectification).

FAQ

Why does a transformer need AC?
The voltage ratio works because the primary's alternating current keeps the core flux changing, and only a changing flux induces a voltage in the secondary (Faraday's law). Connect DC and the flux is steady: no output, and the primary may overheat.

Does stepping voltage down create free power?
No. An ideal transformer conserves power: Vp × Ip = Vs × Is. Stepping the voltage down by 12 multiplies the available current by 12. Real transformers deliver slightly less out than they take in — the difference becomes heat.

How do I work out the turns for a voltage I want?
Pick the turns ratio first: Ns ÷ Np must equal Vs ÷ Vp. For 240 V → 12 V the ratio is 1 : 20, so any pair with that ratio works in theory (e.g. Np = 1000, Ns = 50); in practice designers choose counts that suit the core size and wire thickness.