Transformer Calculator – Turns Ratio & Secondary Voltage
Use this free Transformer Calculator to find the output (secondary) voltage of a transformer from the input voltage and the number of turns on each coil, using Vs/Vp = Ns/Np.
Formula
Vs ÷ Vp = Ns ÷ Np → Vs = Vp × (Ns / Np) • for an ideal transformer, Is = Ip × (Np / Ns)
How to use
- Enter the primary (input) voltage and the number of turns on the primary coil.
- Enter the number of turns on the secondary coil.
- Click "Calculate" to get the secondary (output) voltage and the turns ratio. If you also enter the primary current, you will get the secondary current for an ideal (100% efficient) transformer.
Worked example
A transformer has a primary voltage of 240 V, with 1200 turns on the primary coil and 120 turns on the secondary coil.
Vs = Vp × Ns ÷ Np = 240 × 120 ÷ 1200 = 24 V.
The turns ratio is 120 : 1200 = 1 : 10, so this is a step-down transformer.
FAQ
Why does a transformer only work with AC?
A transformer works by electromagnetic induction: the changing magnetic field from the primary coil induces a voltage in the secondary coil. AC keeps the field changing; steady DC produces a constant field, so after the first moment nothing is induced.
What is the difference between step-up and step-down?
If the secondary coil has more turns than the primary (Ns > Np), the voltage steps up. If it has fewer turns, the voltage steps down — like the example above, which turns 240 V mains into a safer 24 V.
Does a transformer create extra power?
No. In an ideal transformer the power out equals the power in (Vs × Is = Vp × Ip), so stepping the voltage down steps the current up, and vice versa. Real transformers lose a little energy as heat, so they are not quite 100% efficient.