Resonant Frequency Solver – Find L or C for a Target LC Frequency

Use this free Resonant Frequency Solver when you are designing an LC tank circuit to hit a target frequency: enter the resonant frequency you want plus the capacitor (or inductor) you already have, and the tool finds the partner component value.

L C target f0 given → solve L or C

Formula

Resonance: f0 = 1 / (2π√(LC))  •  solve for inductance: L = 1 / ((2πf0)² C)  •  solve for capacitance: C = 1 / ((2πf0)² L)

How to use

Worked example

Solve for L: you want f0 = 1000 Hz and have a C = 1 µF capacitor.
L = 1 / ((2π × 1000)² × 1×10−6) = 1 / 39.48 = 0.02533 H = 25.33 mH.
Solve for C: with L = 25.33 mH at the same 1000 Hz, C = 1 / ((2π × 1000)² × 0.02533) = 1 µF — the two modes are exact inverses.

FAQ

Why design from a target frequency instead of just measuring?
Radio tuning, filters and oscillators all start from a required frequency. Fixing one component you already own (often the inductor, which is harder to vary) and solving for the other is the fastest design route.

What if no standard value matches the answer?
Pick the nearest preferred value (E6/E12 series) and recompute the actual f0 with a resonance calculator — or use a trimmer capacitor / variable inductor to tune the last few percent.

Does the same formula work for series and parallel LC?
Yes — the resonant frequency f0 = 1/(2π√(LC)) is identical. What differs is the impedance at resonance: minimum (ideally R) for series, maximum for parallel.