Motor Back EMF Calculator – ε = V − IR & Current Under Load

Use this free Motor Back EMF Calculator to find the back EMF of a spinning DC motor, using ε = V − IR, and to see how the current changes when the back EMF changes under load.

V R M I spinning coil generates back EMF ε opposing V

Formula

ε = V − I × R  •  ε = back EMF (V), V = supply voltage (V), I = armature current (A), R = armature resistance (Ω). The spinning motor acts as a generator and produces ε opposing the supply, so only the difference V − ε drives current: I = (V − ε) ÷ R. At start-up the motor is not spinning, ε = 0, and the current is the full V ÷ R.

How to use

Worked example

A motor runs from V = 120 V, drawing I = 8 A, with armature resistance R = 2 Ω.
ε = V − IR = 120 − 8 × 2 = 104 V.
Now load the motor so it slows and the back EMF falls to 96 V:
I = (V − ε′) ÷ R = (120 − 96) ÷ 2 = 12 A.
The motor automatically draws more current exactly when it needs more torque — a beautiful piece of self-regulation. (At the instant of switch-on, ε = 0 and the current would surge to 120 ÷ 2 = 60 A, which is why big motors need soft starters.)

FAQ

What exactly is back EMF?
A motor's coil spins inside a magnetic field, so by Faraday's law it generates its own EMF — like a generator. Lenz's law makes this EMF oppose the supply that created the motion, hence "back" EMF. It grows with speed until it nearly equals the supply voltage.

Why does a stalled motor burn out?
If the shaft jams, the motor stops spinning, the back EMF falls to zero, and the current rises to V ÷ R — often 5–10 times the normal running current. The windings then overheat rapidly unless a fuse or cut-out acts.

Where does the supply power go?
The electrical power drawn, VI, splits into useful mechanical power εI (the back EMF times current) and heat I²R wasted in the armature resistance. A motor is most efficient when R is small, so most of V appears as back EMF.