Venturi Meter Calculator – Flow Rate from Pressure Difference

Use this free Venturi Meter Calculator to find the flow rate in a pipe from a pressure reading. Enter the wide and narrow cross-section areas, the pressure difference between them and the fluid density — the calculator combines the continuity equation with Bernoulli's principle to give the flow rate.

P1 (high) P2 (low) v1 v2 area A1 throat A2

Formula

Throat speed: v2 = √( 2ΔP ÷ ( ρ (1 − (A2/A1)²) ) )

Flow rate: Q = A2 × v2, and the wide-section speed is v1 = Q ÷ A1.

The continuity equation (A1v1 = A2v2) says the fluid must speed up in the narrow throat; Bernoulli's equation then says its pressure must fall. Measuring that pressure drop reveals the flow rate — with no moving parts in the pipe.

How to use

Worked example

Water (ρ = 1000 kg/m³) flows through a venturi with A1 = 0.01 m² and throat A2 = 0.005 m². The pressure drop is ΔP = 5000 Pa. (A2/A1)² = 0.25, so v2 = √( (2 × 5000) ÷ (1000 × 0.75) ) = √13.33 = 3.65 m/s. Then Q = 0.005 × 3.65 = 0.0183 m³/s = 18.26 L/s, and v1 = 0.0183 ÷ 0.01 = 1.83 m/s.

FAQ

Where are venturi meters used?
In water supply, chemical plants, carburettors and aircraft airspeed systems — anywhere you need to measure flow without blocking the pipe or adding moving parts.

Must A2 be smaller than A1?
Yes. The throat must be narrower than the inlet, otherwise there is no speed increase and no pressure drop to measure. The calculator warns you if A2 ≥ A1.

How accurate is this formula?
It is the ideal (frictionless) result. Real venturi meters are very efficient, so a discharge coefficient of about 0.95–0.98 is applied in practice — multiply Q by that factor for a real-world reading.