Inductor Current Calculator – Current Growth in an RL Circuit
Use this free Inductor Current Calculator to find how the current grows in an RL circuit after the switch is closed. Enter the supply voltage, resistance, inductance and time — the calculator shows the current, the final (steady) current and the time constant τ = L/R.
Formula
I(t) = (V/R) (1 − e−Rt/L) • time constant τ = L/R • final current Imax = V/R
How to use
- Enter the DC supply voltage and the total resistance in the RL loop.
- Enter the inductance and pick its unit (H, mH or µH).
- Enter the time since the switch closed and click "Calculate".
Worked example
A 3 H inductor is connected through a 6 Ω resistor to a 12 V supply.
τ = L/R = 3/6 = 0.5 s, and the final current is Imax = 12/6 = 2 A.
After t = 1 s: I = 2 × (1 − e−1/0.5) = 2 × (1 − e−2) = 2 × 0.8647 = 1.73 A — 86.47% of the final value.
FAQ
Why doesn't the current jump straight to V/R?
The inductor opposes any change in current by generating a back-EMF. At the instant the switch closes, the back-EMF equals the supply voltage, so the current starts at zero and only builds up as the magnetic field grows.
What does the time constant mean here?
τ = L/R is the time for the current to reach 63.2% of its final value. After 5τ the current is within 1% of V/R and the inductor behaves like a plain wire (for DC).
What happens when the switch is opened again?
The current decays with the same time constant, I = I₀e−Rt/L. Because the inductor tries to keep the current flowing, opening the switch suddenly can produce a large voltage spike — which is why relays and motors use flyback diodes.