Dielectric Strength Calculator – Maximum Voltage Before Breakdown

Use this free Dielectric Strength Calculator to find the maximum voltage an insulating material can stand before it breaks down and sparks through. Every insulator has a breakdown field: if the field across it passes that value, the material suddenly conducts. The maximum safe voltage is simply the breakdown field multiplied by the thickness. Pick a material — air, mica or paper — or enter a custom breakdown field.

dielectric breakdown! d plate + plate −

Formula

Maximum voltage = breakdown field × thickness  →  Vmax = Ebreakdown × d.
This comes straight from E = V/d: the field in the insulator reaches the breakdown value when V = Ebreakdown × d.

How to use

Worked example

A capacitor uses a mica layer 0.1 mm thick. Mica's breakdown field is 118 MV/m (118 × 10⁶ V/m).
Vmax = 118 × 10⁶ × 0.1 × 10⁻³ = 118 × 10⁶ × 1 × 10⁻⁴ = 11,800 V (11.8 kV).
That is why mica capacitors can work at high voltages even with very thin insulation.

FAQ

What is dielectric strength?
It is the largest electric field an insulating material can withstand without breaking down — measured in volts per metre (V/m), often quoted in MV/m or kV/mm. Past that field the insulator ionises and a spark or arc punches through it.

Why does air break down at about 3 MV/m?
That is why a 1 mm air gap can only hold about 3,000 V. Lightning is air breakdown on a huge scale: once the field in a storm cloud passes roughly 3 MV/m, the air conducts and the charge escapes as a flash.

Does a thicker insulator always help?
Yes — the safe voltage grows in direct proportion to thickness, because what matters is the field V/d. Doubling the thickness doubles the voltage the layer can stand (for the same material).